Turning Space As Defined by the ADA - Technical
Turning Space in State and local government facilities, public accommodations, and commercial facilities, as defined by the Americans with Disabilities Act (ADA), is covered in 2010 ADA Standard 304, Turning Space. Turning space can be a circular space or a T-shaped space. The graphic below is representative of these two spaces.
2010 ADA Standard 304.3.1, [Turning Space] Circular Space, states, “The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with [Standard] 306.”
2010 ADA Standard 304.3.2 [Turning Space] T-Shaped Space, states, “The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum. Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum. The space shall be permitted to include knee and toe clearance complying with [Standard] 306 only at the end of either the base or one arm.”
A turning space is required by the ADA in the following locations:
Toilet/ bathing facilities
U-Shaped kitchens
Dressing/ fitting/ locker rooms
Transient lodging guest rooms
Dwelling units (all rooms on accessible routes)
Patient bedrooms
Holding and housing cells
Saunas and steam rooms
Courtrooms (raised stations served by ramps)
Certain recreation spaces
At 180 degree turns around obstructions less than 48” long (unless route at least 42” wide). See the graphic below.